Knowles Chimney Pros

Gas Fireplace Cleaning in Aliso Viejo for Logs, Inserts and Sealed Units

Thinking About This Job?

On the Job Sheet

Gas leaves no creosote, but it still collects dust, spider webs in the pilot and a white film on sealed-unit glass. We shut the gas, lift out the logs, clean the burner and pilot, wipe the glass and look at the vent end outside. Then the unit is relit, the flame is read for color and shape, and a CO meter is held near the front. Logs return to the layout the manual shows.

Pilot hood and burner ports cleared of dust and webs
Logs lifted out, brushed and returned to the manual's layout
White film removed from sealed-unit glass
Outside vent cap looked at for nests and damage
Test burn with a CO meter reading

What a Gas Fire Leaves Behind

Owners who switch from wood often expect a gas fireplace to need nothing. It needs less, but not nothing. A gas flame is clean only when the air and gas mix right, and the mix drifts. Dust from the room settles on the burner and in the air openings, spiders nest in the pilot tube over summer, and the ceramic logs shift a little each time someone moves them, so the flame starts to hit them in the wrong place and leave black marks. On sealed units, the glass gathers a white haze from the burn, which builds up each season until it bakes on. In the vent, a nest or a piece of debris can sit unseen until the unit spills exhaust back into the room. A yearly service catches each of these before it turns into a repair call or a headache in front of the fire.

The service differs a little between the three gas types. Vented log sets get the logs lifted out and brushed, the burner ports and embers cleared, the damper clamp checked, and the flue looked at for nests or fallen debris. Inserts get the front and glass removed, the burner and pilot cleaned, the fan cleaned if there is one, and the liner top checked from the roof. Direct-vent units get the glass and gasket checked, the burner cleaned, and the outside termination looked at for blockages, plants grown too close and paint or siding that has crept over the opening. Every visit ends with the fire running while a meter samples the room air for carbon monoxide, so you know it is burning clean when we leave. Any reading above the background level is written down with where it came from.

How Often, and How It Is Priced

Once a year is the usual answer, and early fall is the usual time, before the first cool evening in Aliso Viejo when everyone lights their fireplace for the first time. A unit used every night through winter may want a mid-season look; one lit only at holidays can go longer, though the vent should still be looked at each year because nests do not care how often the fire runs. If you have just converted from wood, the first service after a full season is worth booking, since that is when any trouble with how the new appliance and the old chimney get along tends to show up. We note on the service sheet anything that is wearing, such as a pilot that is slow to light or a gasket that is going flat, so you can plan for it.

Service is priced per unit at booking, based on the type: a log set, an insert or a sealed direct-vent unit. If the unit needs a part, such as a new thermocouple, a gasket or a replacement log, we tell you what it is and what it costs and only fit it with your agreement. Some older units have been out of production so long that parts cannot be had; when that is the case, the service sheet says it and sets out the options, which may include a new insert in the same opening at our published $2,700 to $5,400. Book on the contact page and say whether it is logs, an insert or a sealed box behind glass; a model name helps if one is printed on the unit.

How Knowles Chimney Pros Handles It

Options Compared

Wood, logs, insert or direct-vent, each on its own line

Measured First

Opening, hearth and flue sized before any unit is picked

Written Price

You see the figure on paper before work begins

Photo Record

Findings and finished work photographed for your file

Related Jobs

Chimney Sweep

Firebox-to-top brushing that clears soot and glaze, leaving a flue ready for another season of wood or a switch to gas.

Read more

Chimney Inspection

Level 1, 2 or 3 inspection under NFPA 211, read with an eye on what the flue can carry if you move to gas.

Read more

Chimney Repair

Repairs to brick, mortar, crown and flue so the chimney can keep serving a wood fire or safely carry gas.

Read more

Fireplace Inspection

Room-side look at firebox walls, hearth, damper and trim, with notes on what a log set, insert or new surround would need.

Read more

Fireplace Repair

Firebox, damper, hearth and face repairs that put a fireplace back in service for wood or ready it for gas.

Read more

Chimney Level 2 Inspection

Camera footage from inside each flue, with roof and attic checks, before a sale, a new gas appliance or after a strong shake.

Read more

Chimney Cap Installation

Mesh-sided caps measured to each flue, to stop rain and nesting birds and hold embers back. Each is priced after measuring, and the number of flues, the cap size and the metal shape that quote.

Read more

Chimney Flashing Repair

New metal where shingles or tile meet the stack, plus a cricket behind broad chimneys to steer water around.

Read more

Chimney Masonry Repair

Brick, mortar and crown work on masonry stacks, with mortar matched to the age and hardness of the brick.

Read more

Chimney Rebuilds

Partial or full rebuilds for chimneys too far gone to patch, in reinforced brick or as a framed chase with a metal flue.

Read more

Fireplace Cleaning

Ash, soot and stains taken out of the firebox and off doors and face, with damper and hearth looked over.

Read more

Gas Fireplace Repair

Pilots that drop out, igniters that will not catch, valves, remotes and vents on gas logs, inserts and built-in units.

Read more

Fireplace Remodel

New faces, hearths and mantels built around the fireplace you keep or the gas unit you are putting in.

Read more

Fireplace Inserts

Gas or wood inserts set into the opening you already have, lined to the top and connected. Gas models $2,700 to $5,400.

Read more

Pellet Stove Repair

Jammed augers, dead igniters, noisy fans, failed boards and dirty vents on pellet stoves, found and fixed with model parts.

Read more

Wood Stove Repair

Door seals, glass, baffles, firebrick and stovepipe on wood stoves, or a priced swap to gas if you are ready.

Read more

Gas Logs

Vented log sets matched to your opening, with the gas line run, leak tested and the flue kept partly open.

Read more

Chimney Seismic Retrofit

Brick stacks tied back to the house or partly rebuilt in lighter materials, so a quake is less likely to drop them.

Read more

Chimney Crown Repair

Cracked chimney tops sealed or poured new, shaped to throw water clear and leave room for the tile to move.

Read more

Dryer Vent Cleaning

Lint cleared from the dryer duct, from the machine to the outside hood, with airflow checked at the end.

Read more

Chimney Liner Installation

Stainless liners for gas inserts, log sets and stoves, or to restore a cracked clay flue, connected and capped.

Read more

Chimney Leak Repair

Water at the ceiling, mantel or firebox traced to its entry point and stopped. $540 to $3,200.

Read more

Chimney Waterproofing

A breathable repellent brushed onto repaired brick so winter rain stays out of the masonry.

Read more

Chimney Damper Repair

Rusted, warped or stuck dampers freed, repaired or replaced with a throat unit or a top-mounted one.

Read more

Chimney Chase Cover

Rusted or sagging metal lids on framed chimneys replaced with stainless made to measure.

Read more