Why the order matters

A gas conversion is bought twice if it is bought in the wrong order. We have seen owners pay for a new insert, then pay again to pull it out because the flue above it had a cracked tile nobody looked at. The fix for that is dull and cheap by comparison: look inside the chimney first, then choose the appliance.

This post is about that first visit, for Aliso Viejo owners who are done with wood and about to spend money on gas.

What the standard says about a change of fuel

NFPA 211 is the document chimney inspectors work from. It groups inspections into three depths and ties the middle depth, Level 2, to particular moments in a chimney's life. Switching from wood to gas is one of them, as is adding an insert, because the flue is about to carry a different kind of exhaust in a different way.

The reasoning is practical. Wood smoke is hot, dry and sooty. Gas exhaust is cooler and full of water vapor. A flue that coped with wood for thirty years can behave badly once it starts carrying moist gas exhaust: water condenses on cold tile, runs down the joints and soaks the brick from the inside. Knowing the state of the tile before that starts is the point of the visit.

What we look at in a wood flue headed for gas

The Level 2 runs a camera from the firebox to the top of the chimney and records the trip. On a flue that is about to change fuel we pay closest attention to a handful of things.

  • Glazed or heavy creosote. It has to come off before gas goes in, because gas exhaust does nothing to remove it and an insert liner should not sit against it.
  • Cracked, shifted or missing tile. A log set would vent straight through those gaps; an insert liner can bridge them, but we need to know they are there.
  • The inside size of the flue. An insert maker sets a minimum area for its liners, and an oversized old flue can be a problem of its own for a log set.
  • The damper and its frame. A log set needs it clamped open; an insert usually needs it taken out so the liner can pass.
  • The crown and cap at the top. A gas flue still needs a cap, and a split crown lets water into the chimney whatever burns below it.
  • The gas stub, if any, at the hearth: its size, its valve and whether it has been capped properly.

Factory-built fireplaces get the same camera, plus a look at the maker's label so we know what that box is approved to take. Many homes in Aliso Viejo, Laguna Niguel and Mission Viejo have one.

What it costs

A Level 2 inspection is $375 and covers the camera run, the roof and attic checks and a written report with photos and the video. If the flue is too heavily coated for the camera to read the tile, it needs sweeping first; a sweep starts from $405. A Level 1 visual check is $160, and it suits a chimney that already burns gas and is not changing, not one about to be converted.

That is the whole price list for this stage. Everything that follows, from a gas log set to a full liner, is priced from what the camera shows.

How the findings shape the quote

The report ends with a short list of what the chimney needs before each gas option is possible. A typical page reads something like this:

  • Gas log set: sweep, clamp the damper, replace the cracked cap screen
  • Sealed insert: sweep, remove the damper, run liners to the top, new cap
  • Direct vent unit: none of the above, since the old flue is retired and closed off

Seeing the three paths with their prerequisites tends to make the choice for you. If the flue needs relining anyway, an insert costs little more than a log set in chimney work. If the firebox is metal and not approved for an insert, the report says so plainly.

When you are ready to book, name the fireplace type and roughly when the house was built on the quote form and we will set the camera visit.

Questions owners ask at this stage

Can I skip the inspection if I only want gas logs? You can choose to, but the logs will vent through whatever is up there. A log set over a cracked flue is the version of this job we most often get called back to.

Will the inspection tell me which gas option to buy? It tells you which ones the chimney allows and what each would need first. The choice between heat and looks stays yours; our post on gas logs versus an insert sets those out.

Does my city want a permit? New gas line work and new appliances often do. The quote that follows the inspection says whether one applies to your job.

Is the report useful if I sell later? Yes. A dated Level 2 with video is the same document a buyer's agent asks for. Our page on home sale inspections explains how buyers read one.

What happens to the wood gear

Grates, screens and andirons come out before a log set or insert goes in. If you want them gone, say so and we take them away. Ash in the firebox and any wood pieces in the smoke chamber come out with the sweep.